sulfo-Cyanine7 antibody labeling kit provides components to label antibodies and proteins of similar size with the sulfo-Cyanine7 fluorophore. The kit attaches the dye through NHS ester chemistry, which targets primary amines on the protein. Afterward, enclosed spin columns remove excess fluorophore by gel filtration. As a result, the roughly 40-minute protocol yields desalted antibody in PBS buffer for fluorescence-based research workflows.
Key Features and Benefits
- NHS Ester Chemistry: The activated ester reacts with primary amines, such as lysine side chains, to form stable amide bonds.
- Sulfonated Cyanine Dye: Sulfo-cyanine dyes carry sulfonate groups, which generally improve water solubility during aqueous labeling.
- Integrated Purification: Enclosed spin columns remove unbound fluorophore by gel filtration, so cleanup stays within the kit.
- Fast Workflow: The complete protocol requires only around 40 minutes from labeling to purified conjugate.
- Ready-to-Use Output: In addition, the procedure delivers desalted antibody in PBS buffer with an optimal number of fluorophores per antibody.
- Defined Kit Capacity: Each kit supports 10 reactions, with up to 100 µg of antibody per reaction.
Applications
- Antibody Fluorescent Labeling: Researchers use the kit to attach sulfo-Cyanine7 to antibodies and proteins of similar size.
- Immunoassay Development: Fluorescent antibody conjugates are widely used as detection reagents in immunoassays.
- Cellular Imaging: Similarly, dye-labeled antibodies commonly serve as probes for fluorescence imaging of cells and tissues.
- Protein Detection Studies: Amine-reactive cyanine dyes are also widely used to label proteins for binding and detection experiments.
Storage and Handling
- Storage: Store kit components according to supplier specifications, and protect the dye from light as general practice for fluorophores.
- Handling: Because NHS esters hydrolyze in moisture, let reagent vials reach room temperature before opening.
- Preparation: Follow the kit protocol and avoid amine-containing buffers, such as Tris or glycine, which compete with the NHS ester.
- Labeling and Analysis: After spin-column purification, researchers commonly estimate the degree of labeling by absorbance measurement.
The sulfo-Cyanine7 antibody labeling kit combines amine-reactive NHS ester chemistry with built-in gel filtration cleanup. Consequently, it supports fast antibody labeling for immunoassay, imaging, and protein detection research. Each kit covers 10 reactions of up to 100 µg antibody.
AxisPharm offers 5000+ PEG Linkers with high purity. Different kinds of PEG Reagents may be available by custom synthesis.